MIL-C-70724(AR)
Attributes sampling inspection
TABLE III.
Inspection Levels
v
III
Lot Size
*
5
2
to 8
*
5
9
to 15
*
5
16
to 25
26
to 50
32
5
32
13
51
to 90
13
32
91
to 150
20
151
to 280
32
20
32
281
to 500
20
501
to 1200
80
80
32
1201
to 3200
125
32
3201
to 10000
125
50
10001
to 35000
125
50
35001
to 150000
50
150000
to 500000
200
200
50
500001
and over
Numbers under inspection levels indicate sample size; asterisks (*)
indicate one hundred percent inspection. If sample size exceeds
lot size, perform one hundred percent inspection. Accept on zero
and reject on one or more for all inspection levels.
b. Alternative quality conformance provisions . Unless
otherwise specified herein or provided for in the contract,
alternative quality conformance procedures, methods, or equipment,
such as statistical process control, tool control, other types of
sampling plans, etc. , may be used by the contractor when they
provide, as a minimum, the level of quality assurance required by
the provisions herein. Prior to applying such alternative
procedures , methods, or equipment, the contractor shall describe
them in a written proposal submitted to the Government for
evaluation (see 6.9) . When required, the contractor shall
demonstrate that the effectiveness of each proposed alternative is
equal to or better than the specified quality assurance
provision(s) herein. In case of dispute as to whether the
contractor's proposed alternative(s) provides equivalent
assurance, the provisions of this specification shall apply. All
approved alternative provisions shall be specifically incorporated
into the contractor's quality program or inspection system, as
applicable.
4.5.3 Rejection. Failure of the lot to be in accordance
with the applicable drawings and requirements of 4.5.2 shall
result in rejection of the lot.