MIL-PRF-48656B(AR)
TABLE V. Examination for defects
EXAMINATION
CONFORMANCE
REQUIREMENT
INSPECTION
CRITERIA
PARAGRAPH
METHOD
SAMPLE
ACC-
REJ 3/
Critical:
100%
0/1
3.3.1
Visual
1. Head or rim split 1/
3.3.1
Visual
100%
0/1
2. Mashed head 1/
100%
0/1
3.3.1
Visual
3. No primer 1/, 4/
100%
0/1
3.3.1
Visual
4. Cocked primer 1/, 4/
100%
0/1
3.3.1
Visual
5. Inverted primer 1/, 4/
Major:
Level IV 2/
101. Perforated or split case 1/
3.3.1
Visual
102. Cartridge length, max
Level IV
3.3.1
SME
103. Rim thickness, max
Level IV
3.3.1
SME
104. Head diameter, max
Level IV
3.3.1
SME
105. Case diameter, max
Level IV
3.3.1
SME
106. Illegible or missing cartridge
Level IV
3.4.2
Visual
marking 1/
107. Open crimp 1/
Level IV
3.3.1
Visual
108. Defective head 1/
Level IV
3.3.1
Visual
109. Sheared case over head 1/
Level IV
3.3.1
Visual
110. Defective body 1/
Level IV
3.3.1
Visual
111. Battery cup defects 1/
Level IV
3.3.1
Visual
112. Primer above flush 1/
Level IV
3.3.1
SME
Minor:
201. Improper lot number 1/
Level III
3.4.1
4.4.8
Notes:
1/ Refer to shotshell/shotgun section of MIL-STD-636 for Visual Standards of defects.
2/ Levels III and IV refer to those verification levels of Table II attributes sampling plan in
MIL-STD-1916.
3/ Accept on 0 and reject on 1
4/ For Type II cartridges: Critical defect No. 3 becomes Major defect No. 113
Critical defect No. 4 becomes Major defect No. 114
Critical defect No. 5 becomes Major defect No. 115