MIL-C-46577D
4.4.3.2 Cartridge Assembly (see Dwg. D7258802 and Dwg.
D7258803, a detail
of Dwg. 1)7258802).
Category and Defects
Method of Inspection
Critical
1.
Split or perforated case - - - - - - - - - ---- -- -- -- - - - - - - - - - Visual
2. Crack or split in projectile ------------------------ Visual
3. Crimp missing (case-projectile) --------------------- Visual
Major:
Loose primer -- -- - - - - - - - - - - - - - - -- --- ---- - --- - - - - -- - --
101.
Manual
Depth of primer seating -- - - - - -- - - --- - --- -- -- -- - - ----
102.
Gage
Over-all length, max. --- - - - - - - - -- - - - -- - - - - -- - - -- - - - -
103.
Gage
104.
Improper or incomplete crimp (case-projectile) ------
Visual
Profile and alignment, max. -------------------------
105 .
Gage
Corrosion -------- -------- -------- -------- ------- ----
106 .
Visual
Head configuration -- - - - - --- - - -- - - -- - - -- - - -- - - -------
107 .
Visual
Metal sliver on head face - - - - - - -- --- - -- -- -- - - - - - - ---
108.
Visual
109.
Length, case head to centerline of crimp ------------
Gage
Inverted primer -- - -- - - -- - - - - - - -- -- -- - - -- - - - - - - - - ----
Visual
110.
Minor:
visual
201.
Marking incorrect, incomplete, illegible or missing -
Visual
202.
Projectile protective coating damaged or incomplete -
Waterproofing missing around primer - - --- - - -- - ----
Visual
203.
204.
Scratch, dent, buckle, bulge, wrinkle or fold in
case -------- ------- -------- -------- ------- -------
Visual
Rotating band damaged ------- -------- --------------- -
Visual
205.
Primer crimp missing -------- -------- -------- --------
Visual
206.
Visual
207.
Foreign matter, except corrosion --------------------
Incorrect type cartridge or component -------- -------
Visual
208.
Lacquer on primer button -- - - - - --- - ---- ---- --- - -- - -- -
Visual
209.
Gap between nose and adaptor -- - - - - - - - - ----- ----- - - - -
Gage
210.
MIL-STD-651 shall apply in defining and evaluating cartridge visual
defects.
A dead weight load of 60 pounds maximum may be used to insert the
cartridge in the gage.
A metal sliver bridging the primer insulator shall be cause for classi-
fying the cartridge defective.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business