MIL-DTL-10190E (AR)
Table IV. Conformance tests - Continued
DRAWING NUMBER
CARTRIDGE, CALIBER .50, BALL, M33
7553097
CONFORMANCE
CRITERIA
REQUIREMENT
INSPECTION METHOD
EXAMINATION OR TEST
PARAGRAPH
REFERENCE
QTY
Ac
Re
Notes - Continued:
4/. The lot shall be rejected when function and casualty defects plus firing defects
observed in all other firing tests exceed the acceptance number for the cumulative sample
in Table III. If the number of defects found in the first tests exceeds the acceptance
number for the first sample, but is equal to or less than the acceptance number for the
cumulative sample, a second sample consisting of double the quantities specified under
function and casualty shall be fired in the service weapons in which the firing defects
occurred in the first test. If the total number of defects in the combined first and second
sample exceeds the acceptance number for the cumulative sample, the lot shall be
rejected. If, in testing a second sample, defects other than those for which the second
sample is being tested should occur to the extent that they exceed the acceptance number
for the cumulative sample, the lot shall be rejected.