MIL-PRF-70600B
Table IV. Conformance inspection
Requirement Inspection
Examination or Test
Conformance Criteria
Paragraph
Method
Sample
Acc-
Rej
Ambient Hot Cold
3.2.1
4.4.1
Primed case sensitivity
300
1/
3.2.2
4.4.2
Velocity
50
2/
3.2.3
4.4.3
Accuracy
100
3/
4/
3.2.4
4.4.4
Chamber pressure
50
50
50
5/
3.2.5
4.4.5
Function and casualty
300
Examination for defects
See MIL-STD-1916
3.3.1
4.4.7
3.3.2
4.4.8
Projectile weight
20
7/
3.3.3
4.4.9
Projectile lubricant
20
8/
Notes:
1/ The criteria for primed case sensitivity acceptance are contained in 4.4.1.
2/ The average velocity of the sample cartridges shall comply with the requirement of
Table I. If the requirement is not met, the lot is rejected.
3/ The average extreme spread of the sample cartridges shall comply with the
requirement of Table I. If the requirement is not met, the lot is rejected.
4/ The average pressure of the sample cartridges, tested at hot, cold and ambient
temperatures, shall comply with the requirement of 3.2.4. If the requirement is not met,
the lot is rejected.
5/ The criteria for function and casualty of the sample cartridges, tested at hot, cold
and ambient temperatures, are contained in Table VI, Firing defects.
6/ If any cartridge bursts or fragments, the lot is rejected.
7/ The projectile weight of the sample shall comply with the requirement of 3.3.2. If
the requirement is not met, the lot is rejected.
8/ If any cartridge shall fail to have evidence of bullet lubrication, the lot is rejected.
8
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business