MIL-PRF-70600B
Table V. Examination for defects
Inspection
Conformance
Requirement
Method
Classification
Examination
Criteria
Paragraph
Reference
Acc-
Rej
Sample
3/
Critical
1
Head or rim split
100%
3.3.1
Visual
Major
101
Perforated or split case
Level IV 2/
3.3.1
Visual
102
Crooked projectile
Level IV
3.3.1
Visual
103
Cartridge length, max
Level IV
3.3.1
SME
104
Rim thickness, max
Level IV
3.3.1
SME
105
Head diameter, max
Level IV
3.3.1
SME
106
Case diameter, max
Level IV
3.3.1
SME
107
Projectile diameter, max
Level IV
3.3.1
SME
108
Cartridge case length, max
Level IV
3.3.1
SME
Minor
201
Visual defects 1/
Level III
3.3.1
Visual
Improper lot number
202
Level III
3.4.1
Visual
Notes:
1/ Refer to cartridge section of MIL-STD-636 for Visual Standards of defects.
2/ Levels III and IV refer to those verification levels of Table II attributes sampling plan in
MIL-STD-1916.
3/ Accept on 0 and reject on 1.