Quality conformance inspection.
4.4
4.4.1 Inspection lot formation. Inspection lots shall comply
with the lot formation provisions of MIL-A-48078. Each inspection
lot shall contain:
a. Cartridge cases from one interfix lot number from one
manufacturer.
b. Projectile parts from one interfix lot number from
one manufacturer.
c.
Primers from one lot number from one manufacturer.
Propellant from one lot number from one manufacturer.
d.
e. Loaded cartridge case assemblies from one interfix
lot number from one manufacturer.
See MIL-A-48078.
4.4.2 Examination.
a. Sampling plans. Unless otherwise specified in the
Classification of Defects and Test Tables, sampling plans for
major and minor defects shall be in accordance with MIL-STD-105,
Inspection Level II.