MIL-C-60813(AR)
Table III (Cont'd)
1/ No second sample permitted. Lot shall be rejected.
2/ For location of defects indicated by letters in parentheses, see Drawing
C7643674.
3/ A loose flash tube shall carry no penalty.
4/ All stoppages attributable to the ammuntion, with the exception of mis-
fire, complete rupture or failure to extract, observed in all tests shall be
included.
4.3.4 Packaging, packing and marking inspection.- During or immediately
prior to the packaging operation, 100% examination of the cartridges shall be
performed to ascertain that the cartridge type conforms to the drawing.
Occurrence of a high pressure test cartridge shall be classed as a critical
defect. Occurrence of any type other than high pressure test shall be classed
as a major defect. All nonconforming cartridges shall be rejected. Inspec-
tion for packaging, packing, and marking shall be in accordance with MIL-STD-
644, as applicable to the drawing.
4.3.5 Inspection equipment.- The examination and tests shall be made
using the equipment listed on IEL-X10542445.
9
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business