MIL-DTL-1394G(AR)
TABLE IV. Examination for defects Continued
Electric Primer, M52A3B1, Dwg. 7548066
Conformance
Requirement
Inspection
Classification
Examination or Test
Criteria
Paragraph
Method 1/, 3/
Critical
1
Missing, inverted, or insecure support cup
100%
3.2
AAIE
2
Oil or grease on electric primer
100%
3.10
AAIE
3
Inverted button
100%
3.2
AAIE
Major
Visual
Level IV
3.2
Mixed types
101
Visual
Level IV
3.10
Crushed or mutilated
102
Visual
3.2
Level IV
Missing, misplaced, or protruding insulator
103
Visual
3.2
Level IV
No button or insulator covering button
104
Visual
3.10
Level IV
Presence of metal slivers on outside of primer or
105
bridging the primer cup and button across insulator
3.10
Visual
Level IV
Foreign matter other then oil or grease
106
Minor
3.2
Gage
Height
Level II
201
3.2
Gage
Level II
Diameter
202
3.2
Gage
Level II
Depth of button
203
3.2
Level II
Visual
Missing, slipped, or punctured disc
204
Level II
3.2
Visual
205
Cocked support cup
Level II
3.10
Visual 2/
206
Explosive composition on disc or support cup
Level II
3.10
Evidence of poor workmanship
207
Visual
Notes:
1/ ORD-SIP-S314 shall apply in defining and evaluating cartridge visual defects. Defect classifications
of ORD-SIP-S314 are revised as shown in Table V.
2/ Minute particles of explosive material are not cause for rejection.
3/ Automated acceptance inspection equipment (AAIE) shall be used to perform all critical defect
inspections. AAIE shall be in accordance with MIL-A-70625 and approved by the government.
7