MIL-DTL-48623A (AR)
Table IV. Conformance inspections - Continued
DRAWING NUMBER
CARTRIDGE, CALIBER .50, BLANK, M1A1
9326760
CONFORMANCE
REQUIREMENT
INSPECTION METHOD
CLASSIFICATION
EXAMINATION OR TEST 1/
CRITERIA
PARAGRAPH
REFERENCE
209
Nicked or dented primer 1/
3.3
Visual
210
Workmanship 3/
3.2
Visual
Notes:
1/. Refer To MIL-STD-636 for visual defects. While no photographs of blank cartridges
are included in this Standard, the cartridge case defects and primer defects illustrated in
the caliber .50 section can be used. In the event of conflict between paragraphs of this
specification and MIL-STD-636 as to defect classification the classification specified by
specification shall apply.
2/ Cartridge profile failure (requiring more than 80 lbs dead weight to insert in profile
and alignment gage)
3/ Defects other than those listed in MIL-STD-636 (Caliber .50 Section).