MIL-P-45172F(MU)
6.5 Intermediate Point inspection. -The classification of defects identifies
the defect characteristics (among other things) for acceptance inspection.
It may be necessary to modify the sequence of inspection stations to best
suit the manufacturing process. Inspection for defect characteristics
which will be hidden or altered by subsequent processing operations (in-
cluding unrelated operations), should be scheduled to prevent premature
acceptance which could be detrimental to the attainment of optimum product
quality in the end item.
6.6 Defect standards. -The initial supply of defect standards and instruc-
tions for contractor and Government application to the eddy current method
of inspection, will be furnished with the inspection equipment. Replace-
ment standards shall be requisitioned through normal channels by the
Government agency having contract administration responsibility.
Asterisks are not used in this revision to identify changes with
NOTE:
respect to the previous issue due to the extensiveness of the
changes.
Preparing Activity:
Custodian:
Army - MU
Army - MU
Project No. 1305-A704
16
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business