MIL-DTL-12779D
TABLE V. Defect inspections.
Classification.
Examination or Test 1/
Conformance
Requirement
Inspection
Criteria 2/
Paragraph
Method
Reference
Critical
1
No crimp or insufficient
100% &
3.3
Gage
crimp 4/
Level VII
2
Cartridge type, incorrect 5/
100% &
3.3
Visual/Gage
(3)
Level VII
Major
101
No primer (25)
Level IV
3.3
Visual
102
Cocked primer (26)
Level IV
3.3
Visual
103
Inverted primer (27)
Level IV
3.3
Visual
104
Cartridge type, incorrect 5/
Level IV
3.3
Visual/Gage
(3)
105
Corroded or stained, if
Level IV
3.3
Visual
etched (cartridge) (2)
106
Split case below top of wad
Level IV
3.3
Visual
(6)
107
Perforated case Below top
Level IV
3.3
Visual
of wad (7)
108
Draw scratch (case) (8)
Level IV
3.3
Visual
109
Scratch (case) (9)
Level IV
3.3
Visual
110
Beveled underside of head
Level IV
3.3
Visual
(case) (10)
111
Scaly metal (case) (11)
Level IV
3.3
Visual
112
No chamfer of head (rim)
Level IV
3.3
Visual
(case) (12)
113
Loose primer
Level IV
3.3
Visual
114
Missing wad(s)
Level IV
3.3
Visual
115
Opening between wad and
Level IV
3.3
Visual
case wall
116
Dent (case) (28)
Level IV
3.3
Visual
117
Cartridge profile failure
Level IV
3.3
Gage
118
Diameter of head (rim) max
Level IV
3.3
Gage
119
Thickness of head (rim) max
Level IV
3.3
Gage
120
Depth of primer
Level IV
3.3
Gage
9